Measure the ambient noise level in your open‑plan workspace. If your environment is typically 45–65 dB (most active open‑plan offices), the upper‑range Class B (DS,A 28–30 dB) is the optimal specification. If your office is generally below 35 dB (very quiet, low occupancy, extensive acoustic treatment), Class A provides worthwhile additional isolation margin. Class A is also suitable
This is mainly a practical trade‑off. The real‑world acoustic performance difference between the upper‑end Class B (DS,A=29.4 dB, e.g., HIGHKA) and the minimum Class A (DS,A=30.0 dB) is negligible for typical open‑plan applications — a 0.6 dB difference cannot be reliably perceived. However, trade‑offs in weight, cost, assembly speed and re‑locatability can be far more significant.
Very close. The upper limit of Class B is DS,A=29.9 dB, while the lower threshold of Class A is DS,A=30.0 dB. HIGHKA’s 29.4 dB is only 0.6 dB below the Class A threshold — within measurement uncertainty, it is closer to Class A than any other Class B acoustic pod. In terms of real‑world performance, HIGHKA achieves 39.3 dB at
For most commercial open‑plan environments (40–65 dB ambient noise), no—not significantly better. Class A (DS,A ≥ 30 dB) offers additional value for specific use cases such as very quiet offices, regulated industries, and extremely noisy environments. However, for typical open‑plan workspaces, Class B (especially at the upper range, e.g., DS,A=29.4 dB) delivers effective ISE attenuation and speech privacy,
ISO 23351‑1 classifies acoustic pods into five grades: A+ (DS,A ≥ 35 dB), A (DS,A 30–34.9 dB), B (DS,A 25–29.9 dB), C (DS,A 20–24.9 dB), and D (DS,A 15–19.9 dB). Classes A+, A and B deliver effective speech privacy in typical commercial office environments (40–65 dB ambient noise). Classes C and D provide noise reduction but cannot reliably achieve full speech
The minimum verification set for credible ESG-aligned acoustic pod procurement: (1) ISO 23351-1 DS,A from a named independently accredited laboratory — verifiable acoustic performance; (2) EU E1 or CARB Phase II formaldehyde compliance documentation — verifiable material safety; (3) CE and/or UL marking — verifiable safety standard compliance; (4) ISO 9001 quality management certification —
HIGHKA’s key ventilation distinction is the combination of occupancy sensing technology and continuous operation. The microwave radar breathing sensor (0.1-second response, −30°C to 60°C) detects occupancy through respiration rather than motion — meaning ventilation continues throughout stationary focus sessions, not only when the occupant is moving. Many PIR (passive infrared) sensor systems detect motion rather
HIGHKA pods contribute to LEED v4 and BREEAM credits across two primary categories. For Indoor Environmental Quality credits: EU E1 material compliance supports low-emitting materials credits; EN 12464-1-compliant lighting supports lighting quality credits; and ISO 23351-1 acoustic performance supports acoustic performance credits. For Materials and Resources credits: 95% recyclable material content supports recycled content and
Independently verified by SGS — an internationally accredited independent laboratory. ISO 23351-1 DS,A testing requires a standardised laboratory procedure with documented conditions. The test must be conducted by an independently accredited body — self-assessment does not produce ISO 23351-1 DS,A. HIGHKA’s DS,A = 29.4 dB is the result of SGS testing under the ISO 23351-1
EU E1 is the European standard for formaldehyde emissions from wood-based panels — the most stringent mainstream global standard for this material category. It limits formaldehyde emission to a maximum of 0.1 ppm from panel products. In enclosed acoustic pods, where the air volume is small and users spend extended periods in direct proximity to


