For the vast majority of commercial open-plan office environments at typical ambient levels (55–65 dB), Class B (DS,A ≥ 25 dB) is sufficient for ISE elimination and speech privacy. At DS,A ≥ 25 dB, the pod interior falls to approximately 35–40 dB — below the ISE activation threshold for typical ambient levels. HIGHKA’s DS,A =
At minimum, request these five documents before finalising any purchase: (1) ISO 23351-1 test certificate from the named accredited laboratory — not a summary or marketing document, the actual certificate with test conditions and full frequency data; (2) CE Declaration of Conformity; (3) UL listing confirmation; (4) ISO 9001 certificate from an accredited certification body;
Yes — all six HIGHKA models share DS,A = 29.4 dB (SGS/ISO 23351-1). The acoustic performance does not diminish in larger models. The six-model range covers: S (1 person) for individual deep focus and solo calls; M (1–2 persons) for private bilateral conversations and individual work; SL (2 persons) for private two-person meetings and coaching;
Because it determines whether the booth’s systems stay active throughout your focus session or cut out during the stationary work the booth is designed for. PIR (Passive Infrared) sensors detect motion — they deactivate when you stop moving. During a 45-minute writing or analysis session, a PIR sensor may cut off lighting and ventilation 3–5
ISO 23351-1 DS,A from a named independently accredited laboratory — by a significant margin. This is the only acoustic specification that can be verified, compared across suppliers, and directly translated into a prediction of in-booth sound levels and ISE elimination. Every other criterion — ventilation, lighting, materials, portability — supports and enables the acoustic function.