• This depends on the specific use cases the renovation was intended to address. For a typical renovation plan to create 2–3 enclosed call/focus spaces and 1–2 small meeting rooms: a deployment of 3–4 Model S/M pods (individual focus and calls) and 1–2 Model ML/L/XL pods (small‑group meetings) replaces the functional output of the planned construction — at

  • Yes. HIGHKA pods’ material specifications — 95% recyclable materials, EU E1 formaldehyde‑emission compliance, CE, UL, ISO 9001, and SGS certification — are compatible with the material and indoor‑environmental‑quality requirements of LEED v4 and WELL v2. Acoustic performance measured under ISO 23351‑1 test protocol supports WELL v2 Sound concept compliance for enclosed workspaces. Consult your LEED/WELL project team to confirm the specific

  • For a single enclosed 2‑4‑person meeting space: fixed construction upfront $25,000–$40,000, plus $10,000–$20,000 reinstatement at end of 7‑year lease = $35,000–$60,000 total with zero residual asset value. HIGHKA Model ML (2‑4 persons) pod: investment with 8–12‑year lifespan, full asset portability, zero reinstatement cost, and the pod is operational at the next premises from day one of

  • In most jurisdictions, soundproof office pods are classified as movable furniture rather than permanent building improvements, which means they are typically depreciated as business personal property rather than as leasehold improvements. This classification can generate more favourable tax treatment than permanent construction — shorter depreciation schedules, potential eligibility for immediate‑expensing provisions. Consult your finance or

  • Under measurement following ISO 23351‑1 test methodology verified by independent SGS laboratory testing, yes — for the specific use case of speech privacy and cognitive‑focus work. HIGHKA pods achieve DS,A = 29.4 dB speech‑level reduction, with full octave‑band frequency‑response test data available in official test reports. Many commercially renovated rooms achieve similar or lower real‑world performance in field conditions

  • Yes. HIGHKA pods are freestanding and designed to be fully mobile. Relocation within an office — for repositioning based on utilisation data — can be performed by an internal facilities team. The pod should be fully emptied of furniture and personal items before relocation. Larger models (Model L and XL) benefit from two to three team

  • The most reliable indicator is a measured change in the sound level differential between interior and exterior across multiple frequency bands. At initial deployment, establish a baseline measurement: measure ambient noise on the open floor, then measure interior ambient with the pod door closed. Record the differential across test frequencies. Repeat this measurement quarterly as

  • No. High‑pressure water or steam should never be used on any pod surface. Moisture ingress into acoustic panel materials degrades acoustic performance and shifts frequency‑dependent attenuation values. Moisture contact with electronic components — sensor housing, control surfaces, LED system — creates immediate risk of component damage. All cleaning should use damp (not wet) cloths for

  • No. The microwave radar breathing sensor is factory‑calibrated and designed for the full operational lifespan of the pod without recalibration. If sensor response appears to have changed (delayed activation, failure to detect occupancy), the first check should be physical obstructions near the sensor housing, followed by power supply stability. If neither resolves the issue, contact

  • Document the location and nature of the seal damage and report it to your facilities team and HIGHKA customer support immediately. A compromised door seal is the most acoustically significant maintenance issue a pod can develop — even a small breach in seal continuity can measurably reduce noise‑reduction performance across speech‑critical frequency bands. Do not